型 號(hào): | |
所屬分類(lèi): | KANOMAX風(fēng)速儀 |
報(bào) 價(jià): | ![]() |
加野麥克斯KA33熱式風(fēng)速儀是日本加野麥克斯公司KANOMAX KA31風(fēng)速儀的升級(jí)版,KA33風(fēng)速儀具備三級(jí)亮度背光選擇功能。KA33風(fēng)速儀具備數(shù)據(jù)保持和風(fēng)速的快 / 慢速測(cè)試功能。具備電池電量不足的提示功能。 KA33風(fēng)速儀具備風(fēng)速上下限判定測(cè)量模式功能。 KA33風(fēng)速儀具備風(fēng)速的 Z大值、Z小值、平均值的測(cè)量功能
與KA22/31相比,體積縮小30%,電池壽命延長(zhǎng)25%。
3.5inch彩色大屏幕,風(fēng)速、風(fēng)溫、壓力同時(shí)顯示。
數(shù)字、模擬雙視圖顯示、具備三級(jí)亮度背光選擇功能。
具備風(fēng)速判定測(cè)試模式,任意設(shè)置上下限。
具備風(fēng)速統(tǒng)計(jì)計(jì)算功能。
產(chǎn)品參數(shù):
名 稱 | KANOMAX風(fēng)速儀KA33熱式風(fēng)速計(jì) | ||
型 號(hào) | KA23 | KA33 | |
測(cè)試對(duì)象 | 常 溫常圧下潔凈的空氣流 | ||
測(cè)試范圍 ( 分辨率 ) | 風(fēng) 速 | 0.00~ 50.0m /s (0.00~ 9.99m /s 時(shí),分辨率 0.01m /s 。 10.0~ 50.0 m /s 時(shí),分辨率 0.1m /s ) | |
風(fēng) 溫 | - 20.0~ 100.0 ℃ ( 分辨率 0.1 ℃ ) | ||
壓 力 * | 無(wú) | 0.00 ~ ±5.00 kPa( 分辨率 0.01kPa ) | |
測(cè)試精度 | 風(fēng) 速 | 0.00~ 4.99m /s ± 2%FS 5.00~ 50.0m /s ± 2%FS | |
風(fēng) 溫 | ± 0.3℃ ( -20℃ ~ 0℃ , 60℃ ~ 100℃ 范圍內(nèi)為 ± 0.5℃ ) | ||
壓 力 * | 無(wú) | ±0.1kPa | |
測(cè)試機(jī)能 | • 具備三級(jí)亮度背光選擇功能。 • 具備數(shù)據(jù)保持和風(fēng)速的快 / 慢速測(cè)試功能。 • 具備電池電量不足的提示功能。 • 具備風(fēng)速上下限判定測(cè)量模式功能。 • 具備風(fēng)速的 zui大值、zui小值、平均值的測(cè)量功能。 | ||
本體外形尺寸 | 本體: 157 ( W ) × 43 ( H ) × 80 ( D ) mm | ||
箱體: 167 ( W ) × 66 ( H ) × 88 ( D ) mm | |||
探頭尺寸 | zui粗把手部分Ф 15mm ,收起后探頭長(zhǎng)度 140mm ,拉伸后探頭長(zhǎng)度 235 mm . | ||
探頭電纜長(zhǎng)度 | 2.5 m | ||
電 源 | AA 堿性電池 4 節(jié) | ||
電池壽命 | 約 10 小時(shí) (風(fēng)速 5 m /s ,風(fēng)溫 20 ℃ , AA 堿性電池) | ||
使用環(huán)境 | 本 體 | 5 ~ 40℃ | |
探 頭 | -20 ~ 100℃ | ||
保存溫度 | -30 ~ 60℃ | ||
重 量 | 約 450g (含電池、探頭、箱體) | ||
隨機(jī)附件 | 手提箱 1 個(gè);使用說(shuō)明書(shū) 1 本;探頭延長(zhǎng)棒 1 支;靜壓測(cè)試膠管 1.5m * ;
|
Never bring the probe close to a flammable gas atmosphere.
The heated sensor may cause a fire or explosion.
Never touch the sensor.
The sensor is heated during operation. Touching the heated sensor
may cause burns, and may also damage the sensor itself.
Do not disassemble or heat the batteries, or put them into a fire.
This may cause burns and the batteries may burst.
If abnormal noises, smells or smoke occur, or if liquid enters the instrument, turn off the instrument immediay, and remove the batteries or pull out the plug.
There is possibility of malfunction, electric shock, and/or fire. Please contact your local distributor or our service center for repair.
Always unplug the instrument from the electrical outlet when the instrument is not in use.
Failure to do so may cause an electrical shock, fire or circuit damage.
Do not use the instrument in a water vapor atmosphere.
Condensed steam on the sensor will change the heat dissipation rate,resulting in inaccurate measurements. It may also cause damage to the sensor.
This instrument is designed to be used in an environment with a clean air stream without any dust or foreign materials.
Foreign materials may cause damage to the sensor. Also dust or foreign materials on the sensor will impede accurate measurements.
Do not apply force to the sensor.
If the sensor is deformed, the accuracy of the sensor may beaffected.
When measuring, ensure that the direction mark is facing into the airflow.
Otherwise, the measurement may be inaccurate, as some sensors
(uni-directional probes) have a specific directivity.